Home/Systems/RM-PRO/3500MF-FM Glass
RM-PRO · Mechanically fastened structural

RM-PRO™ 3500MF-FM Glass

Face-Mounted Mechanically Fastened Glass Railing System

The premium façade system. Mechanically fastened 6061-T6 at the slab edge, engineered for difficult high-rise interfaces.

What sets it apart: PRO structural performance in a face-mounted condition. The system to specify when the façade detail is difficult and the loads are high.
Face-mountedGlassMechanically fastened
Mounting
Face-mounted
Infill
Glass
Fabrication
Mechanically fastened
Post profile
6061-T6 structural post; precision-machined connections
Glass capture
Separate glass channel
Field adjustment
Fixed once installed
Catalogue
RM Product Line Vol. 2, pp. 27–29
RM-PRO™ 3500MF-FM Glass, catalogue render
FULL WIDTH 1075–1185 mm section · face-mounted 1080 mm elevation · glass infill
Catalogue render · Indicative section & elevation · dimensions per project · not for construction
01

System overview

The RM-PRO™ 3500MF-FM is a premium face-mounted aluminum and glass guard system engineered for high-performance façade applications. Mechanically fastened structural aluminum components combine with laminated safety glass to achieve maximum durability, clean sightlines and reliable structural performance.

Designed for mid-rise and high-rise construction, the system integrates with concrete slabs, steel framing and façade assemblies while maintaining architectural transparency.

02

Configuration

  • Face-mounted structural aluminum guard assembly
  • Mechanically fastened post and rail construction
  • Laminated tempered safety glass infill
  • Modular panel fabrication for consistent quality
  • Custom widths, heights and glass configurations available
  • Compatible with balcony edges, terraces and podium conditions
03

Materials

  • Structural components fabricated from 6061-T6 aluminum for primary load-bearing elements
  • Precision machined connection components for mechanical assembly
  • Tempered laminated safety glass meeting safety glazing requirements
  • Stainless steel hardware and concealed fastening systems
  • Isolation materials used to prevent galvanic interaction
All extrusions supplied by certified North American extrusion manufacturers with mill certification available.
04

Fabrication

  • Mechanically assembled structural components preserve full alloy strength
  • Precision machining maintains consistent tolerances and panel alignment
  • Modular panel fabrication for consistent quality across the elevation
  • Surface preparation completed prior to architectural finishing
05

Mounting & anchorage

  • Face-mounted to structural slab edge, steel framing or embedded plates
  • Anchorage engineered based on substrate and loading requirements
  • Typical anchorage includes mechanical anchors, threaded rod systems or structural fasteners
  • Designed to transfer guard loads directly into primary structure while minimizing façade disruption
  • Drainage and waterproofing coordination accommodated
Shop drawings provided showing anchorage layout and interface details.
06

Performance & code compliance

Designed to meet or exceed:

  • Ontario Building Code guard load provisions (OBC 4.1.5.14)
  • CSA S157 aluminum structural design
  • OBC SB-13 “Glass in Guards” requirements
  • Applicable ASTM glass standards for laminated safety glazing
  • Engineering review of anchorage and load transfer
Testing summaries and engineering documentation available.

See the independent field load test data

07

Finish options

  • Factory powder-coat and Duracron, Acrynar, Duranar (XL) finishes meeting AAMA 2603, AAMA 2604 or AAMA 2605
  • Standard and custom architectural colors available
  • Textured and matte finishes supported
  • Anodized finishes available upon request

Finish specification guide

08

Applications & advantages

Typical applications

  • High-rise residential balconies
  • Podium terraces
  • Luxury residential projects
  • Hospitality developments
  • Commercial façade guard conditions
  • Retrofit slab-edge guard replacement

Advantages

  • Mechanically fastened structural design using 6061-T6 aluminum
  • Reduced heat-affected zones compared to welded systems
  • Clean architectural appearance with minimal visual obstruction
  • High durability in exterior environments
  • Compatible with multiple glass thickness options
  • Engineered anchorage solutions for complex façade conditions
  • Premium positioning within the Railing Masters product line
09

Short-form specification

Ready to paste into Section 05 73 00 (Decorative Metal Railings) or the guard schedule. Project-specific values (glass thickness, guard height, color) are left for the specifier to complete.

Specification text · 3500MF-FM Glass

Guard system: RM-PRO™ 3500MF-FM Glass (Face-Mounted Mechanically Fastened Glass Railing System), as manufactured by Railing Masters Inc., 110 Claireport Crescent, Unit 4, Etobicoke, Ontario.

Fabrication: Mechanically fastened structural aluminum assembly with precision-machined connection components and concealed anchorage; no weld heat-affected zones.

Materials: Structural components of 6061-T6 aluminum; stainless steel fasteners and concealed hardware; isolation materials at all dissimilar-metal interfaces. Extrusions supplied by certified North American manufacturers with mill certification available.

Infill: Tempered laminated safety glass infill in thickness per project design, conforming to OBC SB-13 "Glass in Guards" and applicable ASTM safety glazing standards.

Mounting and anchorage: Face-mounted to structural slab edge, steel framing or embedded plates. Anchorage engineered to project loading requirements; shop drawings showing anchorage layout and panel configuration to be submitted for review.

Performance: Designed to meet or exceed Ontario Building Code guard load provisions (OBC 4.1.5.14) and CSA S157 aluminum structural design.

Finish: Factory-applied powder coat, Duracron, Acrynar or Duranar (XL) coating to AAMA 2603, 2604 or 2605 as scheduled; color per architect's selection.

10

Drawings & downloads

Stamped detail package covering this mounting condition, reviewed 31 July 2025 by F. Alibai, P.Eng. (PEO 100206138).

Reference dimensionValue
Balustrade height1075–1185 mm
Glass panel1185 mm
Post spacing1080 mm typical
Bracket projection180 mm
Face of Slab Railing, stamped elevation and section sheet
Sheet FR-01 / FR-02 · elevation & section · P.Eng stamped 31 July 2025
Drawing packages are project-generic. For a specific project, design is to be reviewed and approved by the project’s professional engineer.
Face of Slab Railing
Face-mounted balustrade: elevation, section and details · Drawing FR-01 / FR-02 · Rev. 02 · 6 sheets · P.Eng stamped
PDF
Specify with confidence

Send us the elevation. We'll send back the system.

Tell us the mounting condition, guard height and code jurisdiction. We'll come back with the recommended system, a stamped detail set and a materials list you can put straight into the spec.

Sales & project enquiriesjames@railingmasters.ca
Office416.674.0718
Mobile647.838.7345
Plant & office110 Claireport Crescent, Unit #4, Etobicoke, ON M9W 6P3